| Voltage supply |
230V AC ± 10%, 45...63 Hz, 50VA |
| Device fuse |
1,0 A M (medium time-lag) |
| Measurement method |
Luminance L20 according to DIN 67524 resp. CIE-88 |
| Max. measurement range |
0....10.000 cd/m² |
| Min. measurement range |
0......1.000 cd/m² |
| |
Please report desired measurement range with your order.
Other measurement ranges by request.
The measurement range is a factory setting and cannot be changed on-site! |
| Output signal |
4,0...20,0 mA |
| |
Load < 250 Ω |
| Output fuse |
32 mA M (medium time-lag) |
| Interference protection |
Line filter for power supply
Micro fuse and suppressing diode for output |
| Connector terminal |
Spring-cage terminal for cable cross sections 0,5...2,5 mm² |
| |
|
| Optical properties |
|
| Visual field |
Adjustable from 10° to 30° (Adaption to mounting site) |
| Lens |
Variable focal length: 75...180 mm |
| |
|
| Physical properties |
|
| Housing |
Stainless steel (mat. No.: 1.4571), double-walled
Requirement class I according to German ZTV-Ing. Teil 5, Abschnitt 4 |
| Cable bushing |
2 x M25 cable glares for outer cable diameter 10…15 mm |
| Dimensions |
Housing without mounting bracket L × W × H = 455 × 175 × 185 mm
Housing with mounting bracket L × W × H = 455 × 175 × 245 mm |
| Protection class |
IP65 |
| Weight |
9,5 kg |
| Temperature range |
Ambient temperature: -30°...+70°C
Storage temperature: -30°...+70°C |
| Mounting position |
Clearance above Camera > 250mm
Clearance behind Camera > 500 mm |