Kontakt DE
 
  BACK       FORWARD  
2.3 LIGHTCONTROLLER LUMATICX ADD-ON MODULES AND ACCESSORIES
 

  Productsearch:  


Click to see a larger image
(Illustration similar)
 

2.3.2 ESPREPORT – „REPORT, Software add-on for light controller LUMaticX“ EN

Product description
  • Software add-on to LUMaticX - light controllers
  • Used for data acquisition and evaluation including project management
  • Executable on computers with Microsoft® Windows® operating systems (from NT version 5.0)
  • Single licence: Can be run on 1 light controller LUMaticX
Your advantages
  • Observation, documentation and archiving of system performance
  • Optimization of the control characteristics of the light controller
  • Detect problems in the lighting installation by comparing it with historical evaluations
  • Cross-project benchmark of lighting systems

Technical specifications
Required operating system Executable on computers with Microsoft® Windows® operating systems (from NT version 5.0)
Recordable and representable data General control parameters
Trigger parameters
System parameters
Presentation of photometric data per day, week, month or year per direction of travel
Representation of luminances, steps, switching frequency and light work
Representation of overlapping or undershooting per lighting level and luminance Lth as coloured area
List of accumulated error messages in plain text
 
To the Flyer: (click)
To the Instructions: (click)

Click to see a larger image
(Illustration similar)
 

2.3.4 ESPTICGEGLI – „MODULE: Backlighting compensation for light controller LUMaticX“ EN

Product description
  • Add-on for LUMaticX – light controllers
  • Used to calculate the current position of the sun, to detect glare by low sun using a separate illuminance sensor and to calculate the required increase of luminance in the threshold zone through the light controller, as the luminance sensors aligned to the gantry can’t capture direct sunlight (glare) due to their positioning and design
Your advantages
  • Automatic adjustment of the lighting in case of glaring due to low position of the sun
  • Safety gain by reducing the brightness difference when entering the tunnel

Technical specifications
Measuring input 1 ×  analogue for vertical luminance sensor Ev
Measuring signal 4,0...20,0 mA
 
To the Flyer: (click)
To the Instructions: (click)

Click to see a larger image
(Illustration similar)
 

2.3.6 ESPTICGS1F – „MODULE: 1 x continuous controlled interior zone for light controller LUMaticX“ EN

Product description
  • Add-on for LUMaticX – light controllers for controlling of an interior lighting
  • Used for continuous, stepless control of the tunnel lighting by outputting an analogue control value (for example, for controlling separate dimmers or dimmable drivers), the actual value is not recorded
  • Processing of 1 x control value (e.g. for dimmers)
Your advantages
  • Adjustment of the luminance through dimming
  • Exact, stepless control of the lighting system
  • Energy savings through good adaptability of the lighting system

Technical specifications
Output 1 × analogue value (e.g. for dimmers)
Output signal 4.0…20.0 mA / burden 1 kOhm
Resolution of  analogue signals 12 Bit, accuracy 0,5%
 
To the Flyer: (click)
To the Instructions: (click)

Click to see a larger image
(Illustration similar)
 

2.3.8 ESPTICGS2F – „MODULE: 2 x continuous controlled interior zone for light controller LUMaticX“ EN

Product description
  • Add-on for LUMaticX – light controllers for controlling of two interior lightings
  • Used for continuous, stepless control of two tunnel lightings by outputting two analogue control values (for example, for controlling separate dimmers or dimmable drivers), the actual values are not recorded
  • Processing of 2 x control value (e.g. for dimmers)
Your advantages
  • Adjustment of the luminance through dimming
  • Exact, stepless control of the lighting system
  • Energy savings through good adaptability of the lighting system

Technical specifications
Output 2 × analogue value (e.g. for dimmers)
Output signal 4.0…20.0 mA / burden 1 kOhm
Resolution of  analogue signals 12 Bit, accuracy 0,5%
 
To the Flyer: (click)
To the Instructions: (click)

Click to see a larger image
(Illustration similar)
 

2.3.10 ESPTICGR1F – „MODULE: 1 x continuous regulated interior zone for light controller LUMaticX“ EN

Product description
  • Add-on for LUMaticX – light controllers for regulation of an interior lighting
  • Used to record the measured value of a separate indoor luminance sensor Lin as an actual value and to provide continuous, stepless regulation of the tunnel lighting by outputting an analogue control value (for example, for controlling separate dimmers or dimmable drivers)
  • Continuous regulation according to the luminance difference method
  • Processing of 1 x luminance value Lin (interior zone)
  • Processing of 1 x control value (e.g. for dimmers)
Your advantages
  • Accurate automatic adjustment of the luminance to the actual requirements through dimming
  • Energy savings through compensation of planning reserves
  • Safety gain through autotracking in case of decrease of luminous flux (e.g. lamp ageing)
  • Ageing of the lamps, pollution of the luminaires and changing reflection properties of the tunnel walls and the road are compensated by the lighting regulation system, as far as this is possible

Technical specifications
Measuring input 1 × analogue value for interior luminance sensor Li
Measuring signal 4.0…20.0 mA / burden 25 Ohm
Galvanic Isolation Isolating amplifier
Output 1 × analogue value (e.g. for dimmers)
Output signal 4.0…20.0 mA / burden 1 kOhm
Resolution of  analogue signals 12 Bit, accuracy 0,5%
 
To the Flyer: (click)
To the Instructions: (click)

Click to see a larger image
(Illustration similar)
 

2.3.12 ESPTICGR2F – „MODULE: 2 x continuous regulated interior zone for light controller LUMaticX“ EN

Product description
  • Add-on for LUMaticX – light controllers for regulation of two interior lightings
  • Used to record the measured values of two separate indoor luminance sensor Lin as actual values and to provide continuous, stepless regulation of two tunnel lightings by outputting two analogue control values (for example, for controlling separate dimmers or dimmable drivers)
  • Continuous regulation according to the luminance difference method
  • Processing of 2 x luminance value Lin (interior zone)
  • Processing of 2 x control value (e.g. for dimmers)
Your advantages
  • Accurate automatic adjustment of the luminance to the actual requirements through dimming
  • Energy savings through compensation of planning reserves
  • Safety gain through autotracking in case of decrease of luminous flux (e.g. lamp ageing)
  • Ageing of the lamps, pollution of the luminaires and changing reflection properties of the tunnel walls and the road are compensated by the lighting regulation system, as far as this is possible

Technical specifications
Measuring input 2 × analogue value for interior luminance sensor Li
Measuring signal 4.0…20.0 mA / burden 25 Ohm
Galvanic Isolation Isolating amplifier
Output 2 × analogue value (e.g. for dimmers)
Output signal 4.0…20.0 mA / burden 1 kOhm
Resolution of  analogue signals 12 Bit, accuracy 0,5%
 
To the Flyer: (click)
To the Instructions: (click)

Click to see a larger image
(Illustration similar)
 

2.3.14 ESPTICPROFI – „MODULE: Profibus for light controller LUMaticX“ EN

Product description
  • Add-on for LUMaticX – light controllers
  • Allows the transmission of photometric data, fault messages and parameters
  • Link to higher-level control systems via fieldbus
Your advantages
  • Interface for the exchange of photometric data, fault messages and parameters
  • The autonomously functioning LUMaticX system thus also becomes part of an overall system

Technical specifications
Fieldbus type Profibus DP according IEC 61158
Interface Wire-connected, max. 12 Mbit/s
Connection Via 9-pole D-Sub connector
 
To the Flyer: (click)
To the Instructions: (click)

Click to see a larger image
(Illustration similar)
 

2.3.16 ESPTIC1ROT – „MODULE: Dimmer pass-through feature for light controller LUMaticX“ EN

Product description
  • Add-on for LUMaticX – light controllers for 1 entrance lighting
  • Required to use dimmers for dimming of several lighting grades
  • Pass-through feature for dimmers by fully automatic actuation of the external contactors
Your advantages
  • Reduction of the required number of dimmers (e.g. only 1/3 required for 3 stages)
  • Achievement of dimming levels which are below that possible for the lamps
  • Best cost-benefit ratio through combination of switching / dimming

Technical specifications
Inputs Feedback- signals via 32 × digital input
(coupling relays 250 V, AC, 2 A, 1 x change-over contact, LED green)
Outputs Switching commands via 32 × digital output
(coupling relays 250 V, AC, 2 A, 1 x change-over contact, LED green)
 
To the Flyer: (click)
To the Instructions: (click)

 1 to 8 out of 8  [ <<  1  >> ]